Elements
The probe breaks event data down into tokens and parses them into elements. Elements are used to assign values to ObjectServer fields; the field values contain the event details in a form that the ObjectServer understands.
The following table describes the elements that the Probe for Alcatel-Lucent ITM-NM/OMS generates. Not all the elements described are generated for each event; the elements that the probe generates depends upon the event type.
Element name |
Element description |
---|---|
$af |
This element contains service affecting flags. Possible values are: SA: Service Affecting NSA: Non Service Affecting |
$a1 |
This element contains extra parameters related to the
alarm. This data originates from the Note: This element is only generated when the probe acquires data
from Lucent OMS.
|
$cat |
This element contains the category of the alarm. Possible values are:
|
$cla |
This element contains the A element. This is the network element that reported the alarm. |
$clf |
This element contains the circuit identifier. |
$clz |
This contains the Z element. This is the network element at the opposite end of the path/circuit that is affected by the alarm generated by the A element. |
$n |
This element contains the name or description of alarm. |
$s |
This element contains the state of alarm. Possible values are: C: Clear A: Active |
$sv |
This element contains the alarm severity. Possible values are: P: Prompt D: Deferred I: Information |
$t |
This element contains the sequence number tag. |
$tm |
This element contains a time stamp. |
$txt |
This element contains an additional text string forwarded with the alarm. Note: This element is only generated when the probe
acquires data from Lucent OMS.
|