Elements

The probe breaks event data down into tokens and parses them into elements. Elements are used to assign values to ObjectServer fields; the field values contain the event details in a form that the ObjectServer understands.

The following table describes the elements that the Probe for Alcatel-Lucent ITM-NM/OMS generates. Not all the elements described are generated for each event; the elements that the probe generates depends upon the event type.

Table 1. Elements

Element name

Element description

$af

This element contains service affecting flags. Possible values are:

SA: Service Affecting

NSA: Non Service Affecting

$a1

This element contains extra parameters related to the alarm. This data originates from the addInfo field in Lucent OMS.

Note: This element is only generated when the probe acquires data from Lucent OMS.

$cat

This element contains the category of the alarm. Possible values are:

  • ENV
  • EQU
  • TRM
  • QOS
  • PRC

$cla

This element contains the A element. This is the network element that reported the alarm.

$clf

This element contains the circuit identifier.

$clz

This contains the Z element. This is the network element at the opposite end of the path/circuit that is affected by the alarm generated by the A element.

$n

This element contains the name or description of alarm.

$s

This element contains the state of alarm. Possible values are:

C: Clear

A: Active

$sv

This element contains the alarm severity. Possible values are:

P: Prompt

D: Deferred

I: Information

$t

This element contains the sequence number tag.

$tm

This element contains a time stamp.

$txt

This element contains an additional text string forwarded with the alarm.