Error messages

Error messages provide information about problems that occur while running the probe. You can use the information that they contain to resolve such problems.

The following table describes the error messages specific to this probe. For information about generic Netcool/OMNIbus error messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide.

Table 1. Error messages

Error

Description

Action

Failed to connect - port_ number

Failed to create listening socket with port number port_number

Failed to select socket for reading - port_number

NerveCenter could not connect to the probe.

Check that the process agent is running.

Check that another process is not using the allocated port.

Failed to get event

Failed to process event

Failed to send event to the ObjectServer

Failed to select socket for reading

This is an internal error.

Contact IBM Software Support.

Failed to retrieve value for property StreamCaptureFile

Failed to retrieve value for property TCPPort

Failed to retrieve value for property Inactivity

No value was set for the property indicated. The probe will use default values for these properties.

Specify values in the properties file for the properties indicated.

Unable to allocate number_of_bytes bytes of memory as buffer space

Unable to allocate number_of_bytes bytes of memory for password

Unable to allocate number_of_bytes bytes of memory for server ID

There is insufficient memory to run the probe.

Make more memory available.