Alarm Example 1 - alarm-event
The following is an example alarm event:
alarm-event
tid <string>
portl <string>
porth <string>
status <char>
category <string>
cond_type <string>
time <long integer>
i2000_tid <string>
sa_status <char>
severity <char>
msp <char>
equip_id <char>
resync <char>
alarm_id <string>
<012><012><012>The following table describes the format of this example alarm event.
Field Name |
Values |
Description |
|---|---|---|
| tid | string | Name of Lucent ITM-SC in XMC. |
| portl | string | Port identifier. Maximum of 50 characters. |
| porth | string | Port identifier. |
| status | char | Alarm status. |
| category | string | Field category. |
| cond_type | string | Condition type of the alarm. |
| time | long integer | Field type integer for UNIX time. |
| i2000_tid | string | Lucent ITM-SC host name. |
| sa_status | S | N | Service Affecting status. |
| severity | P | D | I | Alarm severity. Possible values are:
These values are related to major, minor, and warning, respectively. |
| msp | Y | N | Possible values are Yes ( |
| equip_id | char | Equipment identifier. Maximum 50 characters. |
| resync | char | Alarm resynchronization. Possible values are |
| alarm_id | string | Field alarm identifier. |