Known Issues in Netcool/OMNIbus Knowledge Library
This section contains the known issues that may occur while using the Netcool/OMNIbus Knowledge Library 4.8:
No event is displayed for the EX_UNITFAULT and EX_CRASH exceptions in the Event List.
These exceptions are for the
traps mpMajHwAlarm, mpMinHwAlarm, mpMajSwAlarm, mpMinSwAlarm sent
from the devices loaded with the MIB named CISCO-LATITUDE.
However, by entering the case values of EX_UNITFAULT and EX_CRASH in the latitude- CISCO-LATITUDE-MIB.user.include.snmptrap.rules and latitude-CISCOLATITUDE- MIB.include.snmptrap.lookup files, you can enable their display in the Event List.
You
can find the case values of the EX_UNITFAULT and EX_CRASH exceptions using the value of EX_SI_BASE.
Table 9 shows method to calculate the case values of the EX_UNITFAULT and EX_CRASH exceptions.
| Exception code | Calculating the case values |
|---|---|
| EX_UNITFAULT | EX_SI_BASE + 129 |
| EX_CRASH | EX_SI_BASE + 73 |