Customizing the rules file to populate the $specificProblem element
The $specificProblem
element is available
for NFM-P for certain types of alarms, for example NobeB alarms. To
populate the $specificProblem
element you need to
customize the nokia_nfmp.rules file.
The probe rules file contains the following lines that
define the specificProblem
element:
#specificProblem is only available starting SAM v12 and above; and applicable
for certain alarm type only (eg: NodeB alarm)
if (exists($specificProblem))
{
$SpecificProblem_T = lookup($specificProblem, SpecificProblem_t)
## Remove hash below to map specific problem with object server field
## @X733SpecificProb = $SpecificProblem_T
}
To make the $specificProblem
element
available, uncomment the following line by removing the hash symbols:
@X733SpecificProb = $SpecificProblem_T
This
will map $SpecificProblem
to the @X733SpecificProb
field.
Alternatively,
you can create a new field in the ObjectServer using Netcool Administrator
and map $SpecificProblem_T
with a new field (for
example @NewField
).
@NewField = $SpecificProblem_T