ProbeWatch messages

During normal operations, the probe generates ProbeWatch messages and sends them to the ObjectServer. These messages tell the ObjectServer how the probe is running.

The following table describes the raw ProbeWatch error messages that the probe generates. For information about generic ProbeWatch messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide, (SC14-7530).

Table 1. ProbeWatch messages

ProbeWatch message

Description

Triggers/causes

Cannot connect to host

The probe is unable to connect to the host.

General connection failure due either to an incorrect setting of the Host or Port property, or to the host refusing a connection request from the probe.

Connection attempted

The probe is trying to establish a connection to the host.

The probe is trying to establish a connection to the host.

Connection Inactive

The probe has not received any events for the period specified by the Inactivity property.

The probe has not received any events for the period specified by the Inactivity property.

Connection lost ...

The probe has lost the connection to the host.

The device has dropped the connection to the probe.

Connection succeeded

The probe has successfully established a connection to the host.

The probe has successfully established a connection to the host.

Disconnection attempted

The probe is attempting to disconnect from the host.

The probe is shutting down or has lost the connection.

Disconnection succeeded

The probe has disconnected from the host.

The probe shut down or lost the connection to the host.

Going Down ...

The probe is shutting down.

The probe is shutting down after performing the shutdown routine.

Login attempted

The probe is trying to log in to the host.

The probe is attempting to log in to the host.

Probe for Lucent ECP 15 Login failed

The probe has failed to log in to the host.

The probe has encountered a problem while logging in. Check that the ChatinString property is specified correctly.

Login succeeded

The probe has logged in to the host.

The probe has logged in to the host.

Logout attempted

The probe is trying to log out from the host.

The probe has received a command to shut down.

Logout failed

The probe has failed to log out from the host.

The probe has encountered a problem while logging out. Check that the ChatoutString property is specified correctly.

Logout succeeded

The probe has logged out from the host.

The probe has logged out from the host.

Timed out while trying to connect to host

The probe has failed to establish a connection to the host.

The probe timed out while trying to make a Telnet connection to the host.

Unable to get events

A problem occurred while receiving events.

Either there was a problem initializing the connection due to insufficient memory or, if this message was sent after some events had been parsed, there was a license failure or a connection failure.