ProbeWatch messages
During normal operations, the probe generates ProbeWatch messages and sends them to the ObjectServer. These messages tell the ObjectServer how the probe is running.
The following table describes the raw ProbeWatch error messages that the probe generates. For information about generic ProbeWatch messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide.
ProbeWatch message |
Description |
Triggers/causes |
---|---|---|
Connection to source lost |
The connection to the XML source has been lost. |
The target system might have disconnected or gone down. |
Failed to open stream capture file Failed to write to stream capture file Failed to close stream capture file |
The probe is unable to use the specified stream capture file. |
Check the permissions set for the file and the directory in which it is being written. Then check the value specified for the StreamCaptureFile property. |
Start resynchronization |
The resynchronization process started. |
The probe started with the InitialResync property set to true. |
Finish resynchronization |
The resynchronization process ended. |
The probe completed the resynchronization process. |