Error messages
Error messages provide information about problems that occur while running the probe. You can use the information that they contain to resolve such problems.
The following table describes the error messages specific to this probe. For information about generic error messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide (SC14-7608).
Error |
Description |
Action |
---|---|---|
Failed to acknowledge some or all alarms Failed to acknowledge alarm: alarm_id Failed to acknowledge alarms: alarms Failed to acknowledge alarms due to unsupported parameter: parameter Failed to acknowledge alarms due to invalid parameter: parameter |
An acknowledgement command, issued using the command line interface, was not acknowledged. |
Check the error message for the source of the error. |
Failed to close ftp connection Failed to close file |
The probe failed to close a file handle. |
Contact IBM Software Support. |
CLI requested resynchronization, but failed due to exception |
A resynchronization command, issued using the command line interface, failed due to the exception given in the error message. |
Examine the probe log for more information about this error. The probe log can be found in the following location: $OMNIHOME/log/alcatel_xmc_corba.log |
Cannot parse Any attribute with type type |
The probe cannot parse the attribute named in the error message. |
Contact IBM Software Support. |