Alarm Example 2 - dcs-tevnt

The following is an example alarm event:
dcs_tevnt
tid <string>
model <string>
dcs_gen <string>
action <char>
status <char>
time <long integer>
i2000_tid <string>
orig_ems <string>
confirm <char>
<012><012><012>

The following table describes the format of this example alarm event.

Table 1. Example Alarm Event 2 Field Descriptions

Field Name

Values

Description

tid string

Name of Lucent ITM-SC in XMC.

model string

Possible values are:

WS_OLS80G_SE

WS_OLS80G_DF

WS_OLS80G_REPEATER

dcs_gen string

Maximum of 12 characters.

action A | U | D | R

Alarm action.

status I | O | U | D

Alarm status.

time long integer

Field type integer for UNIX time.

i2000_tid string

Lucent ITM-SC host name.

orig_ems string

Maximum of 20 characters.

confirm char

Alarm confirmation.