Filtering alarms
You can restrict the alarms that the probe retrieves to a range of CA Spectrum severity values. Alarm filtering is only available when the AllAlarmsOnRestart property is disabled (set to 0).
Use the MinSpectrumSeverity property to specify the minimum severity level threshold. The probe will not monitor alarms below this severity level. The default is 0 (CA Spectrum severity Normal).
Use the MaxSpectrumSeverity property to specify the maximum severity level threshold. The probe will not monitor alarms above this severity level. The default is 6 (CA Spectrum severity Initial).
The following table lists the available CA Spectrum severity
levels:
Severity level |
Description |
---|---|
0 |
Normal |
1 |
Minor |
2 |
Major |
3 |
Critical |
4 |
Maintenance |
5 |
Suppressed |
6 |
Initial |