Connecting to the CORBA interface

The probe acts as an Integration Reference Point (IRP) Manager and connects to the Nokia-Siemens EMS using a CORBA 3GPP interface.

The AlarmIRPOperation and NotificationIRPOperation points form a part of the IRP Agent to which the probe connects.

Depending on your operating environment, use one of the following connection configurations:
  1. Option 1 - specify values for the following properties:
    • AlarmIrpFile - specify the name used to resolve the Alarm IRP in the CORBA Naming Service.
    • NotificationIrpFile - specify the name used to resolve the Notification IRP in the CORBA Naming Service.
  2. Option 2 - specify values for the following properties:
    • NamingServiceHost - specify the name of the host machine where the CORBA Naming Service is running.
    • NamingServicePort - specify the port on which the CORBA Naming Service listens.
    • AlarmIrpName - specify the name used to resolve the Alarm IRP in the CORBA Naming Service.
    • NotificationIrpName - specify the name used to resolve the Notification IRP in the CORBA Naming Service.
  3. Option 3 - specify values for the following properties:
    • EntryPointIrpFile - specify the location of the file that contains the Interoperable Object Reference (IOR) of the EntryPoint IRP object.
    • NotificationIrpName - specify the name used to resolve the Notification IRP in the CORBA Naming Service.
    • AlarmIrpName - specify the name used to resolve the Alarm IRP in the CORBA Naming Service.