ProbeWatch messages
During normal operations, the probe generates ProbeWatch messages and sends them to the ObjectServer. These messages tell the ObjectServer how the probe is running.
The following table describes the ProbeWatch messages that the probe generates. For information about generic Netcool/OMNIbus ProbeWatch messages, see the IBM Tivoli Netcool/OMNIbus Probe and Gateway Guide.
ProbeWatch message | Description | Triggers or causes |
---|---|---|
Unable to get events; Caused by: EIF Hearbeat failures exceeded: no events received for HeartBeatInterval seconds. |
The number of heartbeat failures specified by the EIFHeartBeatFailures property has been exceeded and the probe will shut down. |
The probe will automatically shutdown when the number of failed heartbeat messages exceeds the number specified by the EIFHeartbeatFailures property. |
Failed to open stream capture file Failed to write to stream capture file Failed to close stream capture file |
The probe has encountered an error with the stream capture file. | The specified file name or the set file permissions are incorrect. |
Going down |
The probe is shutting down. |
The probe is shutting down after receiving a CTRL-C command. |
EIF Heartbeat test failed Unhandled EIFHeartbeat Port |
The probe has failed to send a heartbeat interval message to the Tivoli EIF device. |
The probe is not receiving events from Tivoli EIF. The probe shuts down automatically when the number of failed heartbeat messages exceeds the number specified by the EIFHeartbeatFailures property. |
Running |
The probe has started. |
The probe has started. |