Stabilized feature: Service Flow Runtime and Service Flow Modeler capability in IBM Developer for z/OS 14.2.3 are stabilized. Consider exposing and orchestrating applications as API services by using z/OS Connect Enterprise Edition or CICS® web services, or by writing web applications in Java or Node.js. See also Stabilization notices and discontinued functions.

To apply maintenance or fixes to the runtime environment, use the following process.

About this task

Maintenance is applied using a JCL batch job called DFHMAINA. The JCL is very similar to the DFHMAINJ postinstallation job, in that it contains a subset of the parameters from DFHMAINJ. DFHMAINA invokes a REXX program called DFHMAINX, which looks in member DFHMAINZ for a list of the changed and new members that require maintenance as part of an APAR. DFHMAINZ is updated every time maintenance is applied.

Procedure

  1. Edit the DFHMAINA JCL in the SCIZSAMP library, supplying the same parameter values as you do for DFHMAINJ.
    The parameters that you edit are as follows:
    JOB1
    Together with JOB2 and JOB3, JOB1 is used to create the JCL JOB statements for the required jobs in the .SCIZSAMP library. Do not alter the number of + symbols at the beginning of the statement, because these characters are used to substitute the jobname when DFHMAINJ runs.
    JOB2
    JCL JOB statement continued.
    JOB3
    JCL JOB statement continued.
    SHLQ your.smpe.install.hlq
    A 1-35 character length value that is the data set name high-level qualifier of the CICS SFR SMP/E installation libraries. This value must match what you specified in the previous step for syshlq.
    QUAL your.runtime.library.hlq
    A 1-35 character length value that is the data set name high-level qualifier of the runtime libraries. This value must match what you specified in the previous step for hlqual.
    HLQCICS your.cics.hlq
    A 1-35 character length value that is the high-level qualifier of the CICS libraries.
    HLQCOBOL your.cobol.hlq
    A 1-35 character length value that is the high-level qualifier of the COBOL runtime libraries.
    HLQCEE your.language.environment.hlq
    A 1-35 character length value that is the high-level qualifier of the Language Environment® runtime libraries.
    WSDIR_REQ /your/wsdir/requester/
    The fully qualified name of the Web service pickup directory on zFS that contains the Web service binding file and optionally the WSDL for your Web service requester application. The length of the fully qualified directory name must not exceed 255 characters and must start and end with a /.
    Acceptable characters:
    A-Z a-z 0-9 ./_
    The directory name is case-sensitive.
    CONFIG_REQ /your/pipeline/configuration/requester_config.xml
    The name and location of the requester mode pipeline configuration file in zFS. For example: /usr/lpp/cicsts/samples/pipelines/basicsoap11requester.xml. The pipeline configuration file defines the message handlers that process outbound and inbound Web service requests for your Web service requester application. The length of the fully qualified directory name must not exceed 255 characters and must start with a /.
    Acceptable characters:
    A-Z a-z 0-9 ./_
    The directory and file name are case-sensitive.
    SHELF_REQ your/shelf/directory/
    The fully qualified name of the directory on zFS that contains subdirectories for the requester mode pipeline configuration files and Web service requester binding files. The length of the fully qualified directory name must not exceed 255 characters and must start and end with a /.
    Acceptable characters:
    A-Z a-z 0-9 ./_
    The directory name is case-sensitive.
    WSDIR_PROV /your/wsdir/provider/
    The fully qualified name of the Web service pickup directory on zFS that contains the Web service binding file and optionally the WSDL for your Web service provider application. The length of the fully qualified directory name must not exceed 255 characters and must start and end with a /.
    Acceptable characters:
    A-Z a-z 0-9 ./_
    The directory name is case-sensitive.
    CONFIG_PROV your/pipeline/configuration/provider_config.xml
    The name and location of the provider mode pipeline configuration file in zFS. For example: /usr/lpp/cicsts/samples/pipelines/basicsoap11provider.xml. The pipeline configuration file defines the message handlers that process inbound and outbound Web service requests for your Web service provider application. The length of the fully qualified directory name must not exceed 255 characters and must start with a /.
    Acceptable characters:
    A-Z a-z 0-9 ./_
    The directory and file name are case-sensitive.
    SHELF_PROV /your/shelf/directory/
    The fully qualified name of the directory on zFS that contains subdirectories for the provider mode pipeline configuration files and Web service provider binding files. The length of the fully qualified name must not exceed 255 characters and must start and end with a /.
    Acceptable characters:
    A-Z a-z 0-9 ./_
    The directory name is case-sensitive.
    PREFIX your.prefix
    A 1-7 character length value. The JCL jobname is created as a combination of this value and the name of the member that is customized. For example, if you specify PREFIX CSFR, you will rename every jobname in the members of the runtime SCIZSAMP library with CSFR as the first four characters; for example, //DFHMASET becomes //CSFRASET. If you do not specify a value for this parameter, the sample jobnames are the same as the member names.
    Acceptable characters:
    A-Z a-z 0-9
    The first character of this value must not be a number.
  2. Submit DFHMAINA.
    The job is validated by default. The default is recommended, because any errors in the parameter values are highlighted immediately before the job runs.
    DFHMAINA invokes the REXX program DFHMAINX. This program replaces the SCIZMAC and SCIZLOAD runtime libraries, copies the members listed in DFHMAINZ from the SMP/E SCIZSAMP library to the runtime SCIZSAMP library, and customizes the members using the parameter values that you supplied in DFHMAINA.
  3. Check the output for a return code of 0.
    Each member that is in DFHMAINZ has a Customizing member message associated with it in the output. You will also see the following messages in the //SYSTSPRT of the DFHMAINA job output:
    DFHMAI1002I SCIZSAMP customization beginning
    DFHMAI1011I SCIZSAMP customization ended without errors
    1. If you get a return code of 4 and the following message:
      CICS SFR SCIZSAMP no members to be customized
      No updates were made to the SCIZSAMP library. You can continue to the next step.
    2. If you get a return code of 12 and the following message:
      CICS SFR SCIZSAMP - DFHMAINX could not read member xxxxxxxx
      DFHMAINZ contains a member name that does not exist in the SCIZSAMP library. xxxxxxxx is the name of the unrecognized member.
      Read the PTF documentation to check that the member name in question is supposed to be there. You might have to reapply the fix. If the problem still persists, contact IBM®.