Assembling the SIT

When you have coded the DFHSIT macro, you must assemble the SIT.

About this task

Procedure

  1. Assemble and link-edit the table into an APF-authorized library, such as CICSTS54.CICS.SDFHAUTH.
  2. Include this library in the STEPLIB concatenation of the CICS startup job stream.

Results

If you code a system initialization parameter in your SIT source, and the parameter's keyword is not defined in the CICS-supplied version of the DFHSIT macro, you get an IEV017 warning message from the assembly, as follows:
IEV017  ** WARNING **  UNDEFINED KEYWORD PARAM. DEFAULT TO POSITIONAL, INCLUDING KW  --  OPENC/aaaaaaa

What to do next

For information about assembling and link-editing CICS® control tables, and an explanation of the syntax notation used to describe CICS macros, see Defining resources in CICS control tables.