Assembling the SIT
When you have coded the DFHSIT macro, you must assemble the SIT.
About this task
Procedure
- Assemble and link-edit the table into an APF-authorized library, such as CICSTS54.CICS.SDFHAUTH.
- Include this library in the STEPLIB concatenation of the CICS startup job stream.
Results
If
you code a system initialization parameter in your SIT source, and
the parameter's keyword is not defined in the CICS-supplied version
of the DFHSIT macro, you get an IEV017 warning message
from the assembly, as follows:
IEV017 ** WARNING ** UNDEFINED KEYWORD PARAM. DEFAULT TO POSITIONAL, INCLUDING KW -- OPENC/aaaaaaa