SEND (LUTYPE2/LUTYPE3)

Write data to a 3270-display logical unit (LUTYPE2) or a 3270-printer logical unit (LUTYPE3).

SEND (LUTYPE2/LUTYPE3)

Read syntax diagramSkip visual syntax diagramSENDFROM( data-area)LENGTH( data-value)FLENGTH( data-value)WAITINVITELASTERASEDEFAULTALTERNATECTLCHAR( data-value)STRFIELDDEFRESP

Conditions: INVREQ, LENGERR, TERMERR

Description

The SEND command writes data to a terminal.

Options

ALTERNATE
Sets the terminal to use the ALTERNATE screen size.
CTLCHAR(data-value)
Specifies a 1-byte write control character (WCC) that controls a SEND command for a 3270. These characters are described in IBM 3270 Data Stream Programmers Reference. A COBOL user must specify a data area containing this character. If the option is omitted, all modified data tags are reset to zero and the keyboard is restored.
DEFAULT
Sets the terminal to use the DEFAULT screen size.
DEFRESP
Indicates that a definite response is required when the output operation completes.
ERASE
Specifies that the screen printer buffer or partition is to be erased and the cursor returned to the upper left corner of the screen. This option applies only to the 3270, or 8775, and to the 3604 Keyboard Display.

The first output operation in any transaction, or in a series of pseudoconversational transactions, must always specify the ERASE option. For transactions attached to 3270 screens or printers, unless explicitly overridden by the DEFAULT or ALTERNATE option, this options also ensures that the correct screen size is selected, as defined for the transaction by the SCRNSIZE option in the PROFILE resource definition.

FLENGTH(data-value)
An alternative to the LENGTH option. For architectural reasons, this option is limited to a maximum of 32 KB for all terminal-related SEND commands.
FROM(data-area)
Specifies the data to be written to the logical unit, or a partner transaction.
INVITE
For the SEND (APPC) command, an application can use the INVITE option to add a change-direction indicator to data already sent to a process in a connected APPC system. Control data is not transmitted by CICS® until the subsequent WAIT or a SYNCPOINT command, unless CONFIRM or WAIT is also coded on the GDS SEND INVITE command.

For the other SEND commands, INVITE specifies that the next terminal control command to be run for this facility is a RECEIVE. This allows optimal flows to occur.

LAST
Specifies that this is the last SEND command for a transaction.
LENGTH(data-value)
Specifies the length, as a halfword binary value, of the data to be written. For a description of a safe upper limit, see LENGTH options in CICS commands.
STRFIELD
Specifies that the data area specified in the FROM option contains structured fields. If this option is specified, the contents of all structured fields must be handled by the application program. The CONVERSE command, rather than a SEND command, must be used if the data area contains a read partition structured field. Structured fields are described in IBM 3270 Data Stream Device Guide.)

The CTLCHAR and ERASE options are mutually exclusive with STRFIELD, and their use with STRFIELD generates an error message.

WAIT
Specifies that processing of the command must be completed before any subsequent processing is attempted.

If the WAIT option is not specified, control is returned to the application program when processing of the command starts. A subsequent input or output request (terminal control, BMS, or batch data interchange) to the terminal associated with the task causes the application program to wait until the previous request completes.

Conditions

Some of the following conditions might occur in combination. If more than one occurs, only the first is passed to the application program. EIBRCODE, however, is set to indicate all the conditions that occurred.

16 INVREQ
RESP2 values:
200
A distributed program link server application attempted to send on its function-shipping session (its principal facility).

For SEND (APPC), a distributed program link server application specified the function-shipping session (its principal facility) on the CONVID option.

Also occurs (RESP2 not set) in any of the following situations:
  • The CONFIRM option has been specified, but the APPC conversation is not sync level 1 or 2.
  • The SEND command has been used on an APPC conversation that is not a mapped conversation or that is not using the EXEC CICS interface.

Default action: terminate the task abnormally.

22 LENGERR
Occurs if an out-of-range value is supplied in the LENGTH or FLENGTH option.

Default action: terminate the task abnormally.

81 TERMERR
Occurs for a session-related error. Any action on that conversation other than a FREE causes an ATCV abend.

A CANCEL TASK request by a user node error program (NEP) might cause this condition if the task has an outstanding terminal control request active when the node abnormal condition program handles the session error.