Structure size for system log usage
You can use the z Systems® Coupling Facility Structure Sizer tool (CFSizer), or the formulas provided, to calculate storage requirements for the primary system log, DFHLOG, and the secondary system log, DFHSHUNT.
The CFSizer calculations assume that the coupling facility is at the current CFLEVEL. The formulas provided assume the coupling facility is at CFLEVEL 11.
You use the results of these calculations to set the coupling facility resource manager (CFRM) INITSIZE and SIZE parameters in the CRFM policy.
The primary and secondary log streams must be placed in different structures because of the large disparity in data volumes written to the primary and secondary system logs.
Generally, the volume of data that CICS® keeps in the primary system log at any one time is slightly greater than the amount written during one activity keypoint interval. This volume is determined by the activity keypoint frequency, which is measured in the number of write requests to the CICS system logstream output buffer, and defined on the AKPFREQ system initialization parameter. When you plan coupling facility structure sizes, review the value specified for the AKPFREQ parameter.
Using CFSizer to determine structure size
CFSizer is a web-based application that communicates with a coupling facility at a current CFLEVEL to calculate storage requirements. For primary and secondary system logs, it calculates suitable values for the INITSIZE and SIZE parameters. See System Z Coupling Facility Structure Sizer Tool (CFSizer).
- Maximum buffer size
- The size, in bytes, of the largest log block that can be written to a logstream. The value must be between 1 and 65532. This value corresponds to the MAXBUFSIZE value in the definition of the logstream coupling facility structure. See Defining coupling facility structures.
- Average buffer size
- The average size in bytes of log blocks written to all logstreams.
This input is used to determine the initial entry to element ratio
of the list structure. This value corresponds to the AVGBUFSIZE value
in the definition of the logstream coupling facility structure. See Defining coupling facility structures.
Also, this value is available in the system logger reports produced by IXGRPT1 and IXGRPT1J. See Analyzing system logger data (SMF Type 88 records).
- Highoffload
- The high offload threshold of the logstream. When this percentage
of the coupling facility structure is full, the system logger begins
to offload data from primary storage to offload data sets. For CICS logstreams, this value is
usually between 80 and 85. See Checking logstream status and LOWOFFLOAD and HIGHOFFLOAD parameters on log stream definition.
For more information about the offload threshold parameter, see z/OS MVS Setting Up a Sysplex.
- Number of write requests per interval
- The number of log blocks written to the logstream (the total from
all systems that use the logstream) during the data collection interval.
This value is available in the CICS statistics
reports. See Logstream statistics and Logstreams reports.
Also, this value is available in the #WRITES INVOKED data in the system logger reports produced by IXGRPT1 and IXGRPT1J. See Analyzing system logger data (SMF Type 88 records).
- Length of interval in seconds
- The time interval in seconds over which the number of writes was collected. This value is available in the CICS statistics reports. See Statistics domain: Summary global statistics
- Longest running task in seconds
- The duration in seconds of the longest running transaction during the data collection interval. This is not the average response time.
- Log tail deletes
- The number of times CICS performed log tail deletion during the data collection interval. This value is available in the CICS statistics reports. See delete requests, stream deletes or logstream deletes in Logstream statistics and Logstreams reports. You can also determine this value by using joblog of the region and counting the number of DFHLG0743 messages that were issued during the interval.
Calculation of INITSIZE for DFHLOG
INITSIZE = 310 + ( LOGSNUM * A * B / 1024)where:A = 2000 + (number_of_entries + 5)B = (AVGBUFSIZE * 1.1289) + 195
number_of_entries,
use the following formula: number_of_entries = ((akpintvl + trandur) * writespersec) / 0.9 where:
akpintvlis the interval between activity key points, which varies with workload. Calculate it as follows:
where:akpintvl = AKPFREQ / ((N1 * R1) + (N2 * R2) + (Nn * Rn) )N1, N2 .... Nnis the transaction rate for each transaction (transactions per second).R1, R2 .... Rnis the number of log records written by each transaction.
tranduris the execution time (between sync points) of the longest-running transaction that runs as part of the normal workload.If this duration is longer than theakpintvlvalue, you have the following choices:- Increase the value of the AKPFREQ parameter,
thus increasing the value of
akpintvl, provided that the value does not result in an unacceptably large coupling facility structure size. - Change the application logic to cause more frequent sync points.
- Calculate a structure size based on a shorter transaction duration, and accept that DASD offloading occurs when the long-running transaction is used.
- Increase the value of the AKPFREQ parameter,
thus increasing the value of
writespersec = lesser of 25 or ((N1 * R1) + ... (Nn * Rn)), where:N1, N2 .... Nnare the transaction frequencies (transactions per second) of the most frequently run transactions.R1, R2 .... Rnis the number of log records written by each transaction.
AVGBUFSIZE for
the primary system log, DFHLOG, you can use the weighted average of
the data logged by the most frequently run transactions in the system:
AVGBUFSIZE = (bytespersec / writespersec) + 48 where:
bytespersec = (N1 * D1) + (N2 * D2) + ... (Nn * Dn)N1, N2 .... Nnare the transaction frequencies (transactions per second) of the most frequently run transactions.D1, D2 .... Dnare the bytes of data logged by each transaction.You can calculate the amount of data (Dn) written to the system log for each transaction:
where:Dn = Ns * syncreclen + Nfc * (fcrechdr + fcreclen) + Nts * (tsrechdr + tsreclen) + Ntd * (tdrechdr + tdreclen) + Nur * (urrechdr + urreclen)Nsis the number of sync points per transaction; usually 1.synreclenis the sync point record length.Nfc, fcrechdr, fcreclenare the number of recoverable updates made, the length of the record headers, and the length of the records for file control, respectively.Count only READ UPDATE and WRITE ADD records.
fcrechdris 144 (136 bytes of record header plus 8 bytes of file name).Nts, tsrechdr, tsreclenare for recoverable temporary storage updates.Count only TS PUT and TS UPDATE records. For TS PUT records,
tsrechdris 108, andtsreclenis 88. For TS UPDATE records,tsrechdris 108, andtsreclenis 52.Ntd, tdtrechdr, tdreclenare for recoverable transient data updates.tdrechdris 108, andtdreclenis 380.Nur, urrechdr, urreclenare for user records written to DFHLOG.urrechdris 125.
- See Writes per second calculation for
details of how to calculate
writespersec.
AVGBUFSIZE that
is greater than the value defined for MAXBUFSIZE, the value defined
for MAXBUFSIZE is taken as the value for AVGBUFSIZE,
and writespersec is calculated as follows: writespersec = bytespersec / (MAXBUFSIZE - 48)Round the final result of the INITSIZE formula up to the next multiple of 256.
Calculation of SIZE for DFHLOG
SIZE = 480 + ( LOGSNUM * A * B / 1024)where:A = 2500 + (number_of_entries + 5)B = (AVGBUFSIZE * 1.6821) + 289
To calculate a value for number_of_entries,
see number of entries calculation.
Round the final result of the SIZE formula up to the next multiple of 256. The formula for SIZE gives a result that is approximately fifty percent greater that the INITSIZE value.
Calculation of LOWOFFLOAD for DFHLOG
LOWOFFLOAD = (trandur * 90) / (akpintvl + trandur) + 10 (where RETPD=0 specified)LOWOFFLOAD = (trandur * 90) / (akpintvl + trandur)(where RETPD=dddd specified)
akpintvlis the interval between activity key points. See activity key point interval calculation.tranduris the execution time, between sync points, of the longest-running transaction that runs as part of the normal workload.If this duration is longer thanakpintvlvalue, you have the following choices:- Increase the value of the AKPFREQ parameter,
thus increasing the value of
akpintvl, provided that this value does not result in an unacceptably large coupling facility structure size. - Change the application logic to cause more frequent sync points.
- Calculate a structure size based on a shorter transaction duration, and accept that DASD offloading occurs when the long-running transaction is used.
- Increase the value of the AKPFREQ parameter,
thus increasing the value of
For a description of the low offload threshold for a logstream, see LOWOFFLOAD and HIGHOFFLOAD parameters on log stream definition.
Calculation of INITSIZE and SIZE for DFHSHUNT
INITSIZE = (150 * LOGSNUM) + 310SIZE = (230 * LOGSNUM) + 480
LOGSNUM is number of logstreams that