Write data to a 3650 (3680) logical unit.
SEND (3650-3680)
>>-SEND--FROM(data-area)--+-LENGTH(data-value)--+--+------+----->
'-FLENGTH(data-value)-' '-WAIT-'
>--+--------+--+-----------+--+-----+--------------------------><
+-INVITE-+ +-CNOTCOMPL-+ '-FMH-'
'-LAST---' '-DEFRESP---'
Conditions: INVREQ, LENGERR, TERMERR
Description
SEND writes data to a terminal.
Options
- CNOTCOMPL
- Indicates that the request/response
unit (RU) sent as a result of this SEND command
does not complete the chain. If this option is omitted and chain assembly
is specified, the RU terminates the chain.
- DEFRESP
- Indicates that a definite response
is required when the output operation completes.
- FLENGTH(data-value)
- An alternative to the LENGTH option.
For architectural reasons, this option is limited to a maximum of
32 KB for all terminal-related SEND commands.
- FMH
- Specifies that a function management
header is included in the data to be written. If the ATTACHID option
is specified as well, the concatenated FMH flag is set in the attach
FMH.
The use of FMH is optional and is not supported for all terminal
types. If not supplied, CICS® takes
no action, except for 3600/4700 terminals, where an FMH is mandatory.
In this case, if FMH is not specified, CICS supplies
one and places it in the first 3 bytes of the message, which you must
reserve for this purpose.
- FROM(data-area)
- Specifies the data to be written to
the logical unit, or a partner transaction.
- INVITE
- For the SEND (APPC)
command, an application can use the INVITE
option to add a change-direction indicator to data already sent to
a process in a connected APPC system. Control data is not transmitted
by CICS until the subsequent WAIT or
a SYNCPOINT command, unless
CONFIRM or WAIT is also coded on
the GDS SEND INVITE command.
For the other SEND commands, INVITE specifies
that the next terminal control command to be run for this facility
is a RECEIVE. This allows optimal flows to occur.
- LAST
- Specifies that this is the last SEND
command for a transaction.
- LENGTH(data-value)
- Specifies the length, as a halfword
binary value, of the data to be written. For a description of a safe
upper limit, see LENGTH options in CICS commands.
- WAIT
- Specifies that processing of the command
must be completed before any subsequent processing is attempted.
If
the WAIT option is not specified, control is returned
to the application program when processing of the command starts. A
subsequent input or output request (terminal control, BMS, or batch
data interchange) to the terminal associated with the task causes
the application program to wait until the previous request completes.
Conditions
Some
of the following conditions might occur in combination. If more than
one occurs, only the first is passed to the application program. EIBRCODE,
however, is set to indicate all the conditions that occurred.
- 16 INVREQ
- RESP2 values:
- 200
- A distributed program link server application attempted to send
on its function-shipping session (its principal facility).
For
SEND (APPC), a distributed program link server
application specified the function-shipping session (its principal
facility) on the CONVID
option.
Also occurs (RESP2 not set) in any of the following
situations:
- The CONFIRM option has been specified, but the
APPC conversation is not sync level 1 or 2.
- The SEND command has been used on an APPC conversation
that is not a mapped conversation or that is not using the EXEC CICS interface.
Default action: terminate the task abnormally.
- 22 LENGERR
- Occurs if an out-of-range value
is supplied in the LENGTH or FLENGTH option.
Default action: terminate the task abnormally.
- 81 TERMERR
- Occurs for a session-related
error. Any action on that conversation other than a FREE causes an
ATCV abend.
A CANCEL TASK request by a user node error program
(NEP) might cause this condition if the task has an outstanding terminal
control request active when the node abnormal condition program handles
the session error.
Default action: terminate the task abnormally