For SQL Server, initialize new databases and upgrade
your existing schemas and data so that your databases work with the
new version of IBM Business
Automation Workflow.
Figure 1. Sample environment after existing schemas and data are updated.
The source environment is not running and the databases are not in
use. The databases contain updated schemas and data. The target is
not running but contains a deployment environment.
Run the DBUpgrade command to modify
your existing database schemas and data for use with IBM Business
Automation WorkflowV19.0.0.3. The DBUpgrade utility
updates the following items to V19.0.0.3:
System Data toolkit
Heritage Process Portal process
application
Hiring Sample tutorial process application
Important: Although the DBUpgrade utility
installs the System Data toolkit V19.0.0.3, the
utility does not automatically update existing dependencies. Therefore,
test your applications after migration. If they are not compatible
with the new version of Business Automation Workflow, you
can update the dependencies so that your applications continue to
use the previous version.
Before you begin
Ensure that you have shut down the source
environment before you proceed with the migration.
If
you are migrating from IBM Business Process
Manager V7.5.x
and you get an OutOfMemory error indicating too many or too large
data records, increase the heap size of the JVM for the DBUpgrade command.
Open the DBUpgrade.sh file in install_root/bin and
find -Xmx2048m in this file. This parameter indicates
that the maximum JVM heap size is 2048 megabytes. Increase this value
to update the heap size.
Verify that
the users that are configured to access your SQL Server databases
have the necessary privileges to upgrade the databases. The following
database privileges are needed to modify existing SQL Server database
schemas and data for use with Business Automation WorkflowV19.0.0.3.
The CONNECT and CREATETAB privileges are required on the database
level.
The upgrade process accesses system tables. Grant the SELECT privilege
to the user who performs the upgrade. These privileges are already
granted to the public group by default; it is not necessary to grant
them again unless they were revoked.
Do not grant the sysadmin server role to users.
If a user has the sysadmin role, dbo will
always be the default schema no matter what schema you assign. As
a result, migration will use dbo to create new tables
or update data.
For
a list of supported database versions, refer to the system requirements.
For each deployment environment that
you are creating, complete the following steps:
Copy the whole folder target_deployment_manager_profile/dbscripts/Upgrade/ to
your database computer.
If you did not create a new messaging
engine database and instead you plan to reuse your previous messaging
engine database and schema, you must manually drop the existing messaging
engine tables for each one.
Tip: The messaging engine table names use the SIB prefix.
On the database computer, upgrade all schemas. To see which schemas
are upgraded, go to the directory where you copied the Upgrade folder and see
the upgradeSchemaScriptsHelp_de_name.txt file.
Go to the directory where you copied the Upgrade folder and run the
upgradeSchemaAll command. There is a different
upgradeSchemaAll command for each deployment environment in the source.
Important: If you are using Windows Authentication, you cannot run
upgradeSchemaAll and must run the SQL scripts directly using an SQL
session.
upgradeSchemaAll_de_name.sh
You are prompted to enter the user name and password for each database
connection. This command initializes the new database components and upgrades the schemas of all the
existing databases except for the Workflow Server
and Performance Data Warehouse databases. Those two databases are upgraded later by the
DBUpgrade command.
Alternatively, if you want to run the SQL scripts manually, use an SQL session and run the
scripts in the sequence listed in the
Upgrade_folder/upgradeSchemaScriptsHelp_de_name.txt
file and use the following parameters and commands.
-e specifies that the command is to be echoed on prompt
-b specifies that the script is to exit when errors occur
-U specifies the user name
-P specifies the password
-i specifies the input file
-o specifies that all output is to be redirected to a file
Important: If you are migrating from IBM BPM Express, you must run the table creation file for
IBM Content
Navigator. The file is in
Upgrade_folder/cell_name.DE_name/db_type/icn_database.icn_schema/createTable_ICN.sql.
You might see warning messages when you run the scripts to upgrade the Business Space database
telling you that the result of a query is an empty table or that no row was found for FETCH, UPDATE,
or DELETE. These messages can safely be ignored.
The result.log files are found in
Upgrade_folder/cell_name or
cell_name.de_name/database_type/database_name.schema_name.
Copy the sample migration.properties file
and rename it to target_migration.properties.
Update the file with the configuration information for the target
environment.
Check all the target properties and edit them
if required, following the instructions in the sample file. The sample
file is in install_root/util/migration/resources/migration.properties.
Specify target environment values for
the following properties:
admin.username and admin.password:
Use the cellAdmin user or the WebSphere primary administrative user
name.
bpm.home: The installation root of your target
product. Make sure that the file separators are forward slashes (/).
Use the full path. Do not use the tilde character (˜) to stand for
the home directory. For example:
bpm.home=/opt/IBM/BPM
bpm.home=C:/IBM/BPM
profile.name: The target deployment manager
profile.
target.config.property.file: The full path
of the configuration properties file that you used to create your
target environment.
You must specify the source cluster names, not target cluster
names, for the following properties:
source.application.cluster.name
source.messaging.cluster.name
source.support.cluster.name
source.web.cluster.name
To upgrade the databases to V19.0.0.3, run
the DBUpgrade utility on the deployment manager
computer in the target environment. The DBUpgrade command
automatically upgrades the schema and data for Workflow Server and
Performance Data Warehouse.
Tip: By default, DBUpgrade upgrades
both the schema and data for Workflow Server and
Performance Data Warehouse databases. For instructions for running
the schema update separately, see the DBUpgrade troubleshooting
topic.
Important: Ensure that
your deployment manager and all the managed nodes in the source environment
have been stopped before running this utility.
target_migration_properties_file is
the full path to the migration properties file in which you specified
the configuration information for the target environment.
The
command displays each database upgrade action as it runs. After all
the upgrades are finished, you see a message similar to the following
message:
All upgrade steps have been completed successfully.
The
log location is listed in the output. If there are errors or exceptions,
they appear in the log.
If you are migrating from IBM Business Process
Manager V7.5.x
and you get an out-of-memory error indicating too many or too large
data records, you can try to increase the heap size of the JVM for
the DBUpgrade command. Open the DBUpgrade.sh file
in install_root/bin and find -Xmx2048m in
this file. It indicates that the maximum JVM heap size is 2048 megabytes.
You can increase this value to update the heap size.
If necessary for troubleshooting, you can run DBUpgrade
-generateSQLOnly to generate the SQL files without running them. You can then edit the
generated SQL files manually and run DBUpgrade -omitSQLGeneration to upgrade the
database using the modified files.
What to do next
You might see warning
messages similar to the following in the upgrade log: Couldn't
load Resource META-INF*****. These messages can safely be
ignored.