Check the following table for possible problems and solutions:
Problem/Symptom |
Solution |
The Server Adapter displays as Disabled. |
Perform the following steps to clear the problem:
- Verify that Enable for Business Processes is
selected.
- Verify Sterling Connect:Enterprise® for UNIX is
running.
- Verify the host, port, id, and password used to configure the
Server Adapter are valid for the remote node. Maximum number of characters
for the password is 55.
- Change the name of your Server Adapter. Sterling Connect:Enterprise business
process protocol daemons must register with a unique name. Another
Server Adapter may already be registered with the name of your adapter.
- Verify that you have a valid Sterling B2B Integrator license
key for Sterling Connect:Enterprise UNIX Server. To check, browse to Operations > System > Logs.
View the ceuinterop log.
|
A business process does not start as expected
when a batch is added to a mailbox. |
Perform the following steps to clear the problem:
- In Sterling Connect:Enterprise,
see cmucheckcfg to verify the acd and
referenced remote block (rsd) are valid.
- Verify the acd file includes the .acd file name extension.
- In Sterling Connect:Enterprise,
perform a cmurefresh to force Sterling Connect:Enterprise to
read all acd fields again.
- Verify that the rsd remote id and password
are valid in a Sterling B2B Integrator User
Account.
- Verify that the acd schedule includes the
entry MODE=SENDONLY.
- Verify the mailbox access is not set to restrict reads, writes,
and directory listings.
- In Sterling B2B Integrator,
verify that the rsd remote id (which maps to a Sterling B2B Integrator User
Account) has privileges to execute the business process.
- Verify the acd schedule file includes the following entries defined
for a triggered autoconnect:
CONTACT = DATA_IMMEDIATE
SENDID
=
BATCHID =
RESOURCE
=
- From the ceuinx install directory, perform
cmusession -g and verify the BP adapter name displays and the host
name is correct.
- Verify the PUT options on the rsd. The trigger flag must be set
to notify the autoconnect daemon.
|
Hyperlinks in Account Reports or Schedule Reports
open the browser, but the page displays a message Login
incorrect, please try again. |
Perform the following steps to clear the problem:
- In Sterling Connect:Enterprise,
verify you are logged in with a remote account defined using the BP
protocol.
- Verify that the rsd remote id and password
are valid in a Sterling B2B Integrator User
Account.
|
CEU Server Add Service
returned an error
CEUInteropException
with a message
Mailbox error:EACCESS
|
Perform the following step to clear the problem:
- In the web administrator Define Mailbox Access,
verify that the permissions for the mailbox are set correctly.
|
Status Report contains ERROR CEUServer- BatchStatusService
- Caught exception of type CEUInterop Exception (or similar) |
Perform the following steps to clear the problem:
- Verify that the user id and password used to configure the Server
Adapter are valid for the Sterling Connect:Enterprise instance.
Maximum number of characters for the password is 55.The user id must
match an rsd file in the remote node.
- Login to the web administrator using the user id and password
specified to test the validity.
|
Receive error exception decrypting passphrase. |
Password exceeds limit of 55 characters in the
Server Adapter. If the Sterling Connect:Enterprise for UNIX password
is longer than 55 characters, it must be changed to 55 characters
or less. |