Testing the Sterling Connect:Enterprise UNIX Server Adapter

If Sterling Connect:Enterprise® for UNIX shuts down while it is connected to Application through the adapter, it will automatically reconnect when Sterling Connect:Enterprise for UNIX restarts.

About this task

To verify that Application and Sterling Connect:Enterprise for UNIX are communicating:

Procedure

  1. Configure the Sterling Connect:Enterprise UNIX Server Adapter and save it. If it enables, you are connected.
  2. To verify the connection in Sterling Connect:Enterprise for UNIX, enter one of the following cmusession commands to find a registered configuration of the adapter.
    To list only registered business process protocols:
    cmusession -u <username> -p <password>
    -g

    To list all registered protocols:

    cmusession -u <username>
    -p <password>

    If the Sterling Connect:Enterprise UNIX Server Adapter name does not appear in the list when you perform the cmusession command, the most frequent problems encountered are:

    • Invalid host IP address or port number
    • The adapter was not enabled when configured
  3. If problems continue, turn on the special ceuinterop.log logging from the Operations menu, Operations > System > Log. All services and the adapter log to this file.

    In addition, error statements are logged in the appserver log file (jboss.log or weblogic.log).