To establish Application and IBM® Sterling Connect:Enterprise® for UNIX for
interoperability, follow this procedure:
Procedure
- Define an account (RSD–remote site definitions) to allow
Application to connect into Sterling Connect:Enterprise for UNIX using Sterling Connect:Enterprise for UNIX.
(This task is optional because the system is delivered with a predefined
account called samp_bp.)
- Define a schedule (ACD–auto connect definitions) to indicate
when to notify Application using Sterling Connect:Enterprise for UNIX.
(This task is optional because the system is delivered with a predefined
schedule called samp_bp.acd.)
- Configure the Sterling Connect:Enterprise UNIX Server Adapter using Application.
(Though the preconfigured adapter, CEU Server Adapter BP, is delivered
with the system, you must supply some additional parameters and enable
the configuration.)
- Test connectivity between Application and Sterling Connect:Enterprise for UNIX.
To do this:
Enable the adapter
Perform cmusession
quick test.
- Run the Interoperability Verification Demonstration.