You can create an operating system level failover with a Windows Cluster Installation (Local Drive).
Install Sterling B2B Integrator on machine
1 using the local drive from machine 1 at port xxxxx. Do not override
the default IP address during the installation or use the default
machine 1 IP address. Apply service packs that needs to be applied
as well.
- Start Sterling B2B Integrator on machine
1 and make sure the application is coming up successfully.
- Get the cluster name and cluster IP address of the Windows cluster configured and
setup.
- Go to the install_dir/install/properties
dir. Backup sandbox.cfg and do the following changes:
EXT_HOST_ADDR= cluster IP address
HOST_NAME=cluster IP address
LOCALHOST=cluster IP address
- Repeat the above installation procedure and testing in
machine 2 nodes base port. Sterling B2B Integrator must be
installed in a local drive tested first.