1GbE 4-port Mezzanine Adapter (e4145616e4140518) and 1GbE 4-port Mezzanine Adapter (e4145616e4140528)

The error IDs for the 1GbE 4-port Mezzanine Adapter Device Driver (e4145616e4140518) and and 1GbE 4-port Mezzanine Adapter Device Driver (e4145616e4140528) are as follows:

ERRID_MUSENT_ADAP_ERR
Indicates that the adapter failed initialization commands. User intervention is necessary to troubleshoot the problem.
ERRID_MUSENT_LINK_DOWN
Indicates that the link between the adapter and the network switch is down. The device driver attempts to reestablish the connection after the physical link is reestablished. When the link is established again, the device driver logs ERRID_MUSENT_RCVRY_EXIT. User intervention is necessary to troubleshoot the problem.
ERRID_MUSENT_RCVRY_EXIT
Indicates that a temporary error (such as link down, command error, or transmission error) is corrected.
ERRID_MUSENT_TX_ERR
Indicates that the device driver has detected a transmission error. The device driver enters an adapter recovery mode in an attempt to recover from the error. If the device driver is successful, it logs ERRID_MUSENT_RCVRY_EXIT. User intervention is not necessary for this error unless the problem persists.
ERRID_MUSENT_EEH_SERVICE_ERR
Indicates that the device driver has detected a error during an attempt to recover from a PCI bus error. User intervention is necessary to troubleshoot the problem.
ERRID_MUSENT_EEH_ENTRY
Indicates that the device driver found Enhance Error Handling (EEH) freeze condition.