AXQ00685EUNABLE TO funcacctype; ENQ RC=retcode, RSN=rsncode
(HEX)
Explanation
The Archive Database that is identified
by the ARCHIVE-DATABASE-CLUSTER-NAME parameter could not be synchronized properly with
other tasks that were also attempting access.
func is the function type, which is either
OBTAIN or RELEASE.
acctype is the access type, which i one of the following:
DB-ALLOC
DB-ACCESS
SV5Q_ENQ
INTCP_ACC
DSN_UOW
retcode is the hexadecimal return code of the ENQ/DEQ macro.
rsncode is the hexadecimal reason code from the ENQ/DEQ macro.
System action
Archive or Restore processing is terminated.
User response
Verify that only one Archive, Restore, or Recycle process is running at a time. If
multiple processes are running simultaneously, wait for those processes to finish and then run the
Archive or Restore process again. Otherwise, contact IBM Software Support.