You can remove and replace either of
the hot-swap redundant power supply
units (PSUs) in the enclosure. These redundant power supplies operate in parallel.
About this task
Notes:
Do not insert a PSU if the PSU slot does not contain a power interposer.
Do not operate an enclosure without a power interposer and PSU in a PSU slot for longer than
5 minutes. Operating for longer than this period might cause the enclosure to shut down due
to overheating.
Remove the replacement PSU from its packaging and have it available before carrying out this
procedure.
No tools are required to complete this task. Do not remove or loosen any screws.
Although many components are hot-swappable, their intended use is only when your system is not
active (no I/O operations). If your system is powered on and processing I/O operations, go to the
management GUI and follow the fix procedures. Initiating the replacement actions without the
assistance of the fix procedures can result in loss of data or loss of access to data.
Be careful when you are replacing the hardware components that are located in the back of the
system. Do not inadvertently disturb or remove any cables that you are not instructed to
remove.
When you replace this part, you must follow recommended procedures for handling
electrostatic discharge (ESD)-sensitive devices.
Procedure
Identify the location of the control enclosure that requires service. The Event Log contains
the enclosure MTM and serial number.
This figure shows the location of the Power Supply Unit 1
1 and Power Supply Unit 2 2 .
Identify the PSU that requires service; the Event Log contains the
ID of the PSU that failed.
Removing the PSU
Release the cable retention clip and disconnect the
power cord from the power supply unit that you are replacing.
Fold out the handle so that it extends
perpendicular to the PSU.
While holding the PSU handle, press and hold the PSU release tab and steadily pull the handle
horizontally to slide the PSU from the node, as shown in this figure.
Support the PSU with your other hand as it is released from the node.
Replacing the PSU
Fold out the handle so that it extends
perpendicular to the PSU.
While keeping the PSU handle extended
and supporting the PSU slide the power supply into the enclosure until the release tab engages with
a click.
Connect the power cord to the power supply and to a properly grounded electrical outlet.
Secure the cable with the cable retention clip
on the rear of the power supply unit.
Note: After the power cord is connected to the
electrical outlet, make sure that the LED indicator on the PSU is
lit.