You must use Datacap Studio to
update any rule, including the Recognize OMR Fields rule.
Procedure
To update the Recognize OMR Fields rule to use RecogOMRThreshold:
- In the Rulesets pane, select the Recognize ruleset
and click Lock/Unlock ruleset to lock the ruleset
for editing.
- Expand the Recognize ruleset, the Recognize
OMR Fields rule, and the Recognition: OMR function.
- Right-click the RecognizeFieldOCR_A action
and choose Remove.
- Click the Actions library tab.
- Expand the Recog_Shared library
and select RecogOMRThreshold.
- Make sure the Recognition:OMR function
is selected in the Rulesets pane.
- Click Add to function at the left
side of the Actions Library pane.
- Select the RecogOMRThreshold action
and set the parameters in the Properties pane
as follows:
- Threshold = 20
- Background = 20
Attention: These values are the starting values,
which you can later recalculate with more accurate values.
- In the Rulesets pane, click Save. Then,
click Lock/Unlock ruleset and choose Publish
Ruleset.