The ManualPageID settings control how AIndex manages pages
and fields with the specified status values.
Procedure
To edit the ManualPageID settings:
- Open the Datacap Web Client,
log on to the TravelDocs2 application, and click the Administrator tab.
- On the Workflow page, expand ManualPageID
Job, and select the ManualPageID task.
- In the Selected task details pane,
select aIndex.aspx in the Program field
under the Parameters section.
- Click Setup.
- In the ManualPageID.set.xml -Webpage dialog window,
enter these values for the corresponding fields:
| Option |
Description |
| Done Page Statuses |
0,49 |
| Validation Statuses |
0,2,99 |
| Done Field Statuses |
0 |
| Ignored Field Statuses |
-1,0 |
| Main Task Profile |
ManualIDValidate |
| RuleRunner Service Log |
3 |
| Batch Log |
1 |
| RRS Type |
LocalRRS |
| WRRS URL |
http://127.0.0.1/RRS/ |
| Template Folder |
C:\Datacap\TravelDocs2\fingerprint |
- Click Save.