Testing the ManualIDValidate rule

Run another batch through the workflow but this time change the page status on one of the pages to start the ManualIDValidate profile.

Procedure

  1. Start and log in to the Datacap Web Client, and click VScan on the Operations tab.
  2. In the VScan window, click Browse, go to C:\Datacap\TravelDocs\images. Select a file and click Open, then click Scan.
  3. When the VScan task displays a message to indicate that the scanning is complete, click OK, click Done then click OK and Stop.
  4. On the Datacap Web Client Operations tab, click Upload.
  5. When the Upload task displays a message to indicate that the task is complete, click OK and then click Stop to return to the Operations tab.
  6. Start Datacap Desktop, log in to TravelDocs, and select the PageID shortcut. When the task completes, click OK.
  7. In the Datacap Web Client Operations tab, click the CreateDocs icon and wait for the task to complete. Then, click Stop.
  8. On the Datacap Web Client Operations tab, click the ManualPageID shortcut.
  9. For the last page, set the document type to Flight and the page type to Air_Ticket. Then, click Anchors to assign the matching fingerprint and register the page, as you did before.
  10. In the batch tree view pane, scroll up to the page list and select the first Rental_Agreement page.
  11. Use the dropdown list to change the document type to Hotel. Then, change it back to Car_Rental. AIndex sets the page status to failed (99).
    Attention: If you want to confirm this status, click Hold to put the batch on hold and then open the file manualpageid.xml in the current batch folder. You see <V n="STATUS">99</V> under page TM000001. Then, reopen the batch by clicking the batch ID on the Datacap Web Monitor tab.
  12. With the Car Rental #1 page displayed, click Submit. AIndex runs the validation rule and changes the page status to 0.
  13. Click Done to complete the batch. Then, click OK and Stop.