KS3G041W [module_name] - RMF SYCHRONIZATION FAILED - RC=[n] - COLLECTION INTERVAL DEFAULTING TO 15 MINUTES
Explanation
This message indicates that an internal error has occurred. Collection for data set groups was specified or defaulted as RMF™, however module [module_name] has not been able to synchronize recording with the RMF interval. RC=[n] indicates the reason that the recording interval defaulted to 15 minutes. Return codes are:
- 0 - OK
- 4 - Interval=0 from API
- 8 - NO STGST address
- 12 - NO RMF routine address
- 16 - Parm area address in R1=0 on entry
- 20 - RMF Routine address is dummy
- 24 - Interval = 0 from control blocks
- 28 - Interval less than 1 minute
- 32 - Load failed for KDFDRMFI
- 36 - KDFDRMFI entry point not found
System action
A 15 minute collection interval is used; processing continues.
User response