Refreshing the Configuration Data Sysplexwide

If you enter command code C for the primary automation manager, a panel similar to Figure 1 is displayed.
Figure 1. INGAMS Command Dialog Panel to Refresh the Configuration
 INGKYAM2                  SA z/OS  - Command Dialogs                           
 Domain ID   = IPUND     ---------- INGAMS   ----------    Date = 07/17/19      
 Operator ID = NETOP1          Sysplex = AOCAPLEX          Time = 17:48:42      
                                                                                
 Specify or revise the following data:                                          
                                                                                
  Configuration data set name  (* for current data set)                                                                           
                      => *(-1)                                        

  Suspend file option =>             (NOSUSPEND, FORCESUSPEND)       
                                                                                
  Target              => AOCAPLEX        System name, domain id or sysplex name       
                                                                                
                                                                                                                                                                          
                                                                                
                                                                                
 Command ===>                                                                   
    PF1=Help     PF2=End      PF3=Return                        PF6=Roll        
                                                              PF12=Retrieve     
  • In the Configuration data set name field, specify the name of the data set containing the automation manager configuration members. The name can be a fully qualified data set name or a generation data group name. You can use * to indicate a reload of the configuration from the data set that was used previously, or a different generation of the previously used GDG.
  • In the Suspend file option field, specify how syntax errors in the suspend file are handled. NOSUSPEND entirely ignores the processing of the suspend file. FORCESUSPEND ignores only the lines with syntax errors; all other lines are processed.
  • In the Target field, specify the name of the system where the automation manager resides. Specifying this is only necessary if the automation manager is not within the local sysplex. You can specify either the system name, the domain, or the sysplex name.