INGWHY
Purpose
The INGWHY command queries the automation manager and the various agents for the reasons why a resource is in the displayed status or why it cannot be brought into the desired status.
Syntax
Parameters
- resource
- Specifies the name of the resource to be analyzed. The format is name/type[/system]. Supported resource types are APL, APG, MTR, and REF.
- TARGET
- For information on the TARGET parameter, see TARGET Parameter.
- OUTDSN
- For information on the OUTDSN parameter, see OUTDSN Parameter. The record length must be at least 80 bytes.
- TIMEOUT
- Specifies the maximum number of seconds the INGWHY command waits for responses from the remote system that the command was sent to. The maximum value is 999 seconds. The default is 30 seconds.
- WAIT
- Specifies the number of seconds to wait before reporting that a timeout occurred if the automation manager does not provide the requested data. The maximum time interval is 999 seconds. If omitted, the time interval is 30 seconds.
- OUTMODE
- For information on the OUTMODE parameter, see OUTMODE Parameter.
Restrictions and Limitations
INGWHY is an analysis support function. There are situations where no reason can be found. If that situation appears, it is recommended to use the existing product commands to analyze manually.
Example cases when no reason is found:
- Transient situations that change during the analysis process.
- Status changes manually done by a user.
Examples
INGKYAN2 SA z/OS - Command Dialogs Line 1 of 16
Domain Id : IPXXG ------------ INGWHY ------------ Date : 02/07/17
Operator Id : OPER1 Sysplex = PROD03_X Time : 19:05:50
Analyzed Resource: IMS1DBRC/APL/SYSA Job Name: IMSCA1RC
Status Compound: AWAITING Desired: AVAILABLE Observed: SOFTDOWN
-------------------------------------------------------------------------------
More: F10/F11
SITUATION:
IMS1DBRC/APL/SYSA is waiting to be started.
REASON 2 OF 2:
IMS1DBRC/APL/SYSA has a dependency on IMSRS/APL/SYSA.
IMSRS/APL/SYSA got a SUSPEND request
The SUSPEND request was issued by OPERID=OPER1.
Request Comment: IMSRS is being serviced till 2pm
ACTION 2 OF 2: INGWHYSA(A0100150)
Refer to your company's rules in order to take the appropriate
action.
Consider the following commands to investigate IMSRS/APL/SYSA:
- INGVOTE
- INGSUSPD
Command ===>___________________________________________________________________
F1=Help F2=End F3=Return F6=Roll
F9=Refresh F10=Previous F11=Next F12=Retrieve
For each situation, there might be more than one reason with a corresponding action. If this is the case, you can press F10 or F11 to roll through the reasons and actions.