INGCF MAINT
Purpose
The MAINT function of the INGCF command is intended to put a coupling facility into or take it out of maintenance mode.
After the corresponding XCF command has been processed the command issues the INGCF command without any positional parameters.
Restrictions
The function requires:
- At least one system in the SA z/OS® sysplex must run z/OS 1.9, or later.
- The MAINT function must be supported by all SA z/OS applications that are involved in command processing.
Example
In the following example, a coupling facility is put into maintenance mode using the command INGCF M cf_name MODE=ON OUTMODE=LINE:
Sysplex . . . . . . : KEY1PLEX
SM process level . : 16
MAINTMODE supported : Y
CF Name M Total KB Free KB Free% V Lvl LP Node Descriptor
------- - -------- ------- ------ - --- -- ------------------------------
CF01 N 457472 165376 36.15 Y 13 1 002064.116.IBM.02.000000099F09
CF02 Y 457472 456960 99.89 Y 13 F 002064.116.IBM.02.000000099F09
*** End of Display ***