R(nnnnnn).RD(m) - Remote Card Reader

The R(nnnnnn).RD(m) statement specifies the characteristics of one card reader at a remote terminal. The value of nnnnnn is the number of the remote terminal, as specified in the RMT(nnnnnn) statement; m is the number of this reader. Readers are numbered consecutively (Rnnnnnn.RD1 to Rnnnnnn.RD7) for the number of readers (NUMRD=n in the RMT(nnnnnn) statement) specified for this remote terminal. For example, if there are three card readers attached to remote terminal 2, the readers are numbered R2.RD1, R2.RD2, and R2.RD3. Use the subscripts (nnnnnn or m) in an ascending range (n-*) to indicate from n to 32767 or, in a descending range (*-n) to indicate 32767 to n, or * to indicate all remote readers. Note that parameter ranging applies to both remotes and remote readers. Characteristics of remote readers are specified by the following parameters.