Missing data in report fields

When a LCU has no activity during the interval, RMF omits that LCU from the report for that interval. If no activity has occurred during the interval for all selected LCUs, the message NO ACTIVITY FOR SELECTED LCUs appears instead of the data after the headings of the report.

If a channel path was brought online or taken offline during the interval, data is formatted and an additional line in the report describes its status. If an installed channel path was offline during the whole interval, the additional line identifies the channel path as OFFLINE. If a channel path was taken offline or brought online during an interval, the additional line identifies the channel path as either NOW OFFLINE or NOW ONLINE.

When RMF cannot obtain valid hardware data for CONTENTION RATE and DELAY Q LNGTH, it prints the message NO H/W DATA under those headings.

If the channel measurement facility is inactive or has been interrupted during the interval, CHANNEL MEASUREMENT FACILITY NOT ACTIVE OR INTERRUPTED appears after the headings where the data normally appears in the report.

If the diagnosis interface fails during the interval, DIAGNOSIS INTERFACE FAILURE appears after the headings in the report.