S550-0433-05
Connectivity test for AFP Download Plus
Appendix F. Connectivity test for AFP Download Plus
When installing AFP Download Plus for the first time, you might want to perform
a connectivity test to an existing receiver before doing a complete,
customized installation. A connectivity test installs AFP Download Plus with
all defaults, provided samples, and minimal space allocations to verify
communication with the receiver.
To perform a connectivity test for AFP Download Plus:
- Make sure that the existing receiver is at the appropriate support
level for AFP Download Plus. See Appendix D. Download receiver support.
- Follow Steps 2 through 8 in Installing AFP Download Plus and make these
changes:
- Create the default /var/psf/ working directory
with a size of 1 MB.
- Configure the AFP Download Plus sender with these suggestions:
- Define only one FSA.
- If you already have PSF or Download for z/OS® installed, use the same work-selection criteria
or change the class.
- Do not configure for MO:DCA IS/3 compliant files.
- If Download for z/OS is
installed, update the EXEC statement to specify PGM=APSHPOSE; otherwise,
do these to create a startup procedure:
- Copy and use the APSWAFPP sample startup procedure in SYS1.PROCLIB.
- Follow the Required Actions in the sample prolog to change the
procedure to run on your system.
- Comment out the AFPPARMS DD statement so you can use all the default
AFPPARMS values.
- Delete all but one FSA.
- Do not create an AFPPARMS data set or use the Printer Inventory.
- Define either JES2 or JES3 initialization statements.
- Do not use any installation exits.
- Use the default program properties table (PPT) entry.
- Start the sender. See Starting the sender and FSAs.
- Update the APSIVPAJ sample installation verification program (IVP)
to use the class that is defined for your AFP Download Plus FSA.
- Submit the job to verify that no terminating errors are issued
and the job is successfully processed by the receiver.
|