z/OS TSO/E Messages
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


IKJ79061I

z/OS TSO/E Messages
SA32-0970-00

IKJ79061I
EBCDIC DATA FOR &SYSTWOBYTE IS OUTSIDE VALID DBCS RANGE.

Explanation

The built-in function &SYSTWOBYTE translates an EBCDIC string into the double-byte character set (DBCS). The valid DBCS code points that correspond to EBCDIC data and can be translated are ‘4040’ and ‘42db’ where db is a code point in the range of ‘41’ to ‘FE’ In this error, the &SYSTWOBYTE built-in function was issued for EBCDIC data outside of the range ‘40’ to ‘FE’ and translation to DBCS was not possible.

To correct the error, remove any EBCDIC data outside of the range ‘40’ to ‘FE’ from the &SYSTWOBYTE string. For more information about &SYSTWOBYTE and DBCS, see z/OS TSO/E CLISTs.

Module

IKJCT439

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014