.-NOEXIT--------------------------------------------.
>>-+---------------------------------------------------+-------><
| .-,-------------------------------------. |
| V .-NOINEXIT-----------------. (1) | |
'-EXIT(---+-+--------------------------+--+-----+-)-'
| '-INEXIT(mod1-+--------+-)-' |
| '-(str1)-' |
| .-NOLIBEXIT-----------------. |
+-+---------------------------+-+
| '-LIBEXIT(mod2-+--------+-)-' |
| '-(str2)-' |
| .-NOPRTEXIT-----------------. |
+-+---------------------------+-+
| '-PRTEXIT(mod3-+--------+-)-' |
| '-(str3)-' |
| .-NOOBJEXIT-----------------. |
+-+---------------------------+-+
| '-OBJEXIT(mod4-+--------+-)-' |
| '-(str4)-' |
| .-NOADEXIT-----------------. |
+-+--------------------------+--+
| '-ADEXIT(mod5-+--------+-)-' |
| '-(str5)-' |
| .-NOTRMEXIT-----------------. |
'-+---------------------------+-'
'-TRMEXIT(mod6-+--------+-)-'
'-(str6)-'
Notes:
- Choose at least one option.
- Default
- NOEXIT
- Abbreviations
- EX(INX, NOINX, LBX, NOLBX, PRX, NOPRX, OBX, NOOBX, ADX, NOADX,
TRX, NOTRX) / NOEX
- Restrictions
- You cannot specify this option on *PROCESS statements.
- INEXIT
- Specifies that the assembler use an input (SOURCE) exit for
the assembly. mod1 is the name of the load module for the exit.
The assembler passes control to the load module for SOURCE type exit
processing, and provides a pointer to str1 in a parameter
list when the exit is first called. For a full description, see Providing user exits.
You can use a SOURCE exit, for example, to read
variable-length source input records. See also Sample SOURCE user exit (z/OS and CMS).
- NOINEXIT
- Specifies that there is no SOURCE exit.
- LIBEXIT
- Specifies that the assembler use a LIBRARY exit for the assembly. mod2 is the name of the load module for the exit. The assembler
passes control to the load module for LIBRARY type exit processing,
and provides a pointer to str2 in a parameter list when the
exit is first called. For a full description, see Providing user exits.
On CMS, you can use this exit, for example, to handle non-standard
libraries, or macros and copy books that are in separate CMS files
instead of CMS MACLIBs.
On z/VSE, you can use this exit to
handle edited macros from the library sublibraries.
Refer to z/VSE: Guide to System Functions for
a description of a LIBRARY exit to read edited macros.
- NOLIBEXIT
- Specifies that there is no LIBRARY exit.
- PRTEXIT
- Specifies that the assembler use a LISTING exit for the assembly. mod3 is the name of the load module for the exit. The assembler
passes control to the load module for LISTING type exit processing,
and provides a pointer to str3 in a parameter list when the
exit is first called. For a full description, see Providing user exits.
You can use the LISTING exit, for example, to suppress parts of the
assembly listing, or provide additional listing lines. See also Sample LISTING user exit (z/OS and CMS).
- NOPRTEXIT
- Specifies that there is no LISTING exit.
- OBJEXIT
- On z/OS and CMS, specifies that the assembler use an OBJECT
exit or PUNCH exit, or both, for the assembly. mod4 is the
name of the load module for the exit. The assembler passes control
to the load module for OBJECT type exit processing when you specify
either the OBJECT or GOFF option, and provides a pointer to str4 in
a parameter list when the exit is first called. For a full description,
see Providing user exits. The assembler passes control to the load module for
PUNCH type exit processing when you specify the DECK option. The OBJEXIT
suboption is ignored if you specify the assembler options NODECK and
NOOBJECT.
On z/VSE, specifies that the assembler use a PUNCH exit
for the assembly. The name of the load module for the exit is mod4.
The assembler passes control to the load module for PUNCH type exit
processing when you specify the DECK option. You can use the PUNCH
exit, for example, to catalog object modules directly into a library
sublibrary.
- NOOBJEXIT
- Specifies that there is no OBJECT exit or PUNCH exit.
- ADEXIT
- Specifies that the assembler use an ADATA exit for the assembly. mod5 is the name of the load module for the exit. The assembler
passes control to the load module for ADATA type exit processing, and
provides a pointer to str5 in a parameter list when the exit
is first called. For a full description, see Providing user exits.
See also Sample ADATA user exits (z/OS and CMS).
- NOADEXIT
- Specifies that there is no ADATA exit.
- TRMEXIT
- Specifies that the assembler use a TERM exit for the assembly. mod6 is the name of the load module for the exit. The assembler
passes control to the load module for TERM type exit processing, and
provides a pointer to str6 in a parameter list when the exit
is first called. For a full description, see Providing user exits.
- NOTRMEXIT
- Specifies that there is no TERM exit.
- NOEXIT
- Specifies that there are no exits for the assembly.
The module names mod1, mod2, mod3, mod4, mod5, and mod6 can refer to the same load module.
The suboptions str1, str2, str3, str4, str5, and str6 are optional. They are character strings,
up to 64 characters in length, that are passed to the exit module
during OPEN processing. You can include any character in a string,
but you must pair parentheses. JCL restrictions require that you
specify two apostrophes to represent a single apostrophe, and two
ampersands to represent a single ampersand.
For more information about the EXIT option, see Providing user exits.
You specify these options in the installation default options using