DFHTC1600 applid The value for SYSIDNT, sysid1, does not match the one specified in the last cold or initial start, sysid2. CICS normal operation may be affected.
Explanation
SYSIDNT has been specified in the SIT or as a system initialization parameter override on a warm or emergency start of CICS. The value of SYSIDNT does not match that specified on the last cold or initial start. SYSIDNT should be updated only on a cold or initial start.
System action
System initialization continues.
User response
For an emergency or warm start of CICS, ensure that SYSIDNT has the same value as in the last cold or initial start. It is recommended that CICS is re-initialized with the appropriate value specified for the SYSIDNT parameter for correct operation of CICS.
Module
DFHTCRPXMEOUT parameters/Message inserts
- applid
- sysid1
- sysid2
Destination
Console
Applicable releases in Version 6
- beta
- 6.3
- 6.2
- 6.1