CDFAE1303E The command failed because the following invalid parameter was specified: parameter-name.

Explanation

You can create and manage user-defined extensions (UDXs) by issuing in-database analytics (IDA) commands. This message is returned when an IDA command is issued, but one of the specified parameters is not valid for that command. For example:

  • A parameter name might have been accidentally misspelled.
  • If a parameter value contains a comma-separated list, if the list is not enclosed in quotation marks, and if there is a blank before one of the items in the list, that item will be interpreted as a parameter and this message will be issued.
  • The version of CLPPlus that you are using might be outdated and unable to recognize parameters that were introduced more recently.

User response

Issue the command again, specifying only parameters that are valid for the command. If you are certain that the specified parameters are all valid, download and install the latest version of the driver package. This will install the latest version of CLPPlus.