Autoinstall control program at INSTALL

The autoinstall control program is invoked at INSTALL for:
  • Local SNA LUs
  • MVS™ consoles
  • Local APPC single-session connections initiated by a CINIT
  • Local APPC parallel-session connections initiated by a BIND
  • Local APPC single-session connections initiated by a BIND
  • Shipped terminals and connections
  • Client virtual terminals.

On each invocation, CICS® passes a parameter list to the control program by means of a communication area addressed by DFHEICAP. The parameter list passed at INSTALL of local terminals and APPC single-session connections initiated by CINIT is described in The communication area at INSTALL for terminals. The parameter list passed at INSTALL of MVS consoles is described in Autoinstall control program at INSTALL. The parameter list passed at INSTALL of shipped terminals and connections is described in The communications area at INSTALL for shipped terminals. The parameter list passed at INSTALL of Client virtual terminals is described in The communications area at INSTALL for Client virtual terminals. This section describes only INSTALL of local APPC connections initiated by BIND requests.