DFHTD0183 applid Unexpected response (code X'response') and reason (code X'reason') from a dfhxxyym call during processing of intrapartition queue queue.
Explanation
The trigger level has been reached for intrapartition transient data queue queue.
Module DFHTDB or DFHTDRM could not initiate the associated transaction following the response of a dfhxxyym call to domain xx.
The response (code X'response') and reason (code X'reason') are those returned from the domain call (that is, xxyy_response and xxyy_reason).
Initiation of the associated transaction has failed.
System action
This is probably a CICS logic error.
Each subsequent write to the transient data queue causes another attempt to initiate the transaction, which will fail. However, this message is only issued the first time the error is detected.
CICS writes a dump and continues processing. Message DFHME0116, which contains the symptom string for this problem, is produced.
User response
If you need further assistance from IBM to resolve this problem, see IBM problem support for guidance on how to proceed.
Module
DFHTDB, DFHTDRMXMEOUT parameters/Message inserts
- applid
- X'response'
- X'reason'
- dfhxxyym
- queue
Destination
Console