RTMC0243E The tpfrtmc offline utility could not parse the properties file that was specified with the command to start the utility.

Last updated

  • Start of changeChanged in 2025.End of change
  • Added in 2021.

Explanation

The command to start the tpfrtmc offline utility was entered. However, the utility could not parse the runtime metrics collection properties file that was specified with the command.

System action

The utility logs the error and shuts down.

User response

Complete the following steps:
  1. Start of changeIf you use Podman and need more information about the cause of the error, enter podman logs container, where container is the name of the tpfrtmc offline utility container.End of change
  2. Ensure that the properties file follows the correct schema.
  3. If the schema is correctly defined, ensure that the properties file is accessible, in the correct format, with the correct file extension, and does not contain garbage data.