X'100C' MSC NOT GEN BUT MSC SEG PRESENT

Explanation

The message was created with an MSC prefix, but MSC is not initialized.

Programmer response

Locate the message and verify that the MSC prefix is present and flag MSGC2MSC is set on. If so, MSC was defined at SYSGEN when the message was created but is not in the SYSGEN now. The flag SCDPDMUL is set on by SYSGEN if MSC is included in the SYSGEN. Do a SYSGEN with MSC.