The OMEGAMON enhanced 3270UI was started in single-sysplex mode; however, processing
failed when attempting to obtain memory to store sysplex configuration information.
System action
The OMEGAMON enhanced 3270UI continues processing with single-sysplex mode
disabled. Other related errors may occur in the case where the address space encounters errors when
attempting to obtain memory.
User response
Review started task and site definitions associated with address space region size.
The OMEGAMON enhanced 3270UI address space is normally started with region size 0M. Adjust the
address space region size as required. If this does not address the issue, collect any related dump,
trace, and system log data along with the OMEGAMON enhanced 3270UI job logs. Report the problem to
IBM Software Support.