KOBCM0049W Receive failed, Err = error code Rsn = reason_code, nnn seconds, retry = n Failed for DRA = Data_Retrieval_Agent_name IP = IP_address, Hub = hub_monitoring_server_name (application_name .table_name)

Explanation

Message KOBCM0049W indicates that a TCP/IP 'receive' failed between this Tivoli® OMEGAMON® Manager and a Data Retrieval Agent (DRA). The error and reason codes are displayed in the Err = nnn and Rsn = nnn fields. Typical values that you might see include: Err=1102 Rsn=0x76650211 The receive attempt 'timed out'. You can find details about the failure by examining the Rsn value. For example, you can enter the following TSO command to get Rsn code details: bpxmtext 76650211.

System action

No results from the failed query are available, so any enhanced 3270 user interface workspace that needs the results might be missing data.

System programmer response

Check that the named DRA is running and not in an abending address space. If this message repeats frequently, adjust your enhanced 3270UI Global Query Timeout value to a larger number of seconds, to allow a longer period for the query to complete. The Global Query Timeout value is found in the Edit->Preferences (E.P) menu, under the Session/Logon tab.