KOBCM0045W RC = return code in DRA = Data_Retrieval_Agent_name IP = IP_address, Hub = hub_monitoring_server_name (application_name .table_name)
Explanation
Message KOBCM0045W indicates that the Data Retrieval Agent (KOBAGENT) was contacted from the Tivoli® OMEGAMON® Manager, but an error was detected in the Data Retrieval Agent. This error indicates that a repeat attempt might be successful.
- RC=5
- The Hub or Remote Tivoli Enterprise Monitoring Server is not yet available.
- RC=79
- When attempting to delete a table row, the row was not found.
- RC=80
- When attempting to insert a table row, a duplicate row was found.
- RC=155
- A hub or remote monitoring server could not be contacted.
- RC=202
- A TEMS does not contain application support for a particular column.
- RC=209
- A monitoring server does not contain application support for a particular application and table.
- RC=3000
- Historical data does not exist for the requested table.
- RC=9036
- The hub monitoring server is not yet available.
- RC=9037
- SQL SELECT string is too long, rejected by the DRA
- RC=9038
- SQL query contains invalid column name, rejected by the DRA
- RC=9999
- The hub monitoring server is not yet available.
- RC=67109015
- A hub or remote monitoring server could not be contacted.
- RC=67109019
- A Hub or Remote TEMS could not be contacted.
- RC=67109066
- A TEMS does not contain application support for a particular column.
- RC=67109073
- A monitoring server does not contain application support for a particular application and table.
If this message occurs frequently, check the RKLVLOG for the Data Retrieval Agent that is listed, which might contain more details. If the message indicates that a remote or hub monitoring server is not yet available, confirm that the monitoring server is running and is not out of storage or abending.
System action
The query, insertion or deletion fails and any enhanced 3270 user interface workspace that needs the results might be missing data.
System programmer response
Check the message details for the particular return code (RC) and take the appropriate action. For example, if the message return code indicates that the monitoring server is not available, check the system to confirm that the monitoring server is running correctly. If the return codes indicate that application support files are missing, apply application support (also known as seeding) to the necessary remote and hub monitoring servers.