KOBCM0035E send block failed, rc = return_code, microseconds = mmm+ extended diagnostics error and context

Explanation

The conduit manager send of the query to the data retrieval agent failed. Return code was return_code. The elapsed time for the connect attempt, in microseconds, is mmm.

System action

This query is bypassed.

User response

If the errno value is EWOULDBLOCK, it is likely the query timed out. Compare the microseconds value to the value found in log message KOBCM0066I. If the microseconds in this message are slightly longer than the time-out value, in seconds, found in KOBCM0066I, then the query took too long to process. Try increasing the time-out value to see if that resolves the problem. Use the command "/F tom,SO_TIMEOUT x" to change the time-out value, where x is the time out in microseconds and tom is the enhanced 3270 address space name. Retry the associated query found in the extended diagnostics. If the problem persists, call IBM Software Support.