KCNPR002I PARMS NOT FOUND. DEFAULTS USED FOR:

Explanation

This message comes from initialization functions in the OMEGAMON® Subsystem (KCNPRSR). There are parameters placed by the Configuration Software in the &hilev.RKANPARU data set to help control Coupling Facility collection in the OMEGAMON Subsystem. The parsing code that reads these parameters is expecting values for four keywords:
  • XCF=
  • REFRESH=
  • PLEXCOLLECT=
  • KCN_WTO=
This message documents those values that are not found. Built in defaults will be used for their value.

System action

None.

User response

None required. If an overriding parameter was specified but not detected, verify that it was spelled correctly, that there are no blanks after the = sign, and that the entire KCNSTR00 member is less than 8880 bytes long.