KDS_X_TEMS_CONFIRM_SHUTDOWN

This parameter specifies the maximum number of seconds between two successive SHUTDOWN commands or MVS™ STOP (P) commands to terminate the monitoring server address space.

Required or optional
Required
Location where the parameter value is stored
KDSSYSIN member of the rhilev.rte.RKANPARU library for the runtime environment of the monitoring server
Parameter name and syntax
CONFIRM(n)
Default value
  • Default for PARMGEN: CONFIRM(0)
  • Default in TMS:Engine: CONFIRM(15)
Permissible values
0 - 2000000000
PARMGEN name
KDS_X_TEMS_CONFIRM_SHUTDOWN
Description
Maximum number of seconds between two successive SHUTDOWN commands or MVS STOP (P) commands to terminate the monitoring server address space. CONFIRM(0) allows shutdown to begin immediately, without an additional, confirming SHUTDOWN command. CONFIRM(n), where n is a number greater than zero, prevents accidental shutdowns by requiring confirmation of the command by entering it a second time within the specified number of seconds. For example, the value 15 requires that the SHUTDOWN command be entered twice within 15 seconds to terminate the monitoring server address space.
Related parameters
  • KDS_HUB_* parameters (values for the Primary HUB TEMS that the z/OS Remote TEMS reports to)