Collecting diagnostic data

If you have a problem that you are unable to solve using the information in this guide, gather the following information that relates to the problem and contact IBM® Software Support for further assistance.

  • Description of the operation scenario that led to the problem.
  • Operating system version and release level.
  • Version, release and fix level of the following members of the monitoring environment:
    • IBM Tivoli® Monitoring Server
    • Tivoli Enterprise Portal Server
    • Monitoring agent
  • If the Windows operating system crashes, collect the drwtsn32.log and user.dmp files, if available. The files are located in the following path:

    \Documents and Settings\All Users\Documents\DrWatson

    See the chapter on diagnostic tools in the IBM Tivoli Monitoring Troubleshooting Guide for more information about trace tools.

    • Enter the following command at the command prompt to enable the Dr. Watson™ tool as default debugger: drwtsn32 –i 2
    • Enter the following command at the command prompt to open the configuration window of the Dr. Watson tool: drwtsn32
  • Include such other documentation as is recommended in Table 6.
  • If possible, try to classify your problem according to a component area listed in Table 7 and collect documentation as listed there.
Table 1. Recommended documentation
  Abend Incorrect output Performance Function Connectivity
LOG X X X X X
Dump X X X    
Screen shots   X   X  
Traces     X    
cinfo output       X  
TEPS database export       X  
LISTDATA output   X   X  
SMF record dump   X      
BVIR dump X X      
RKS3DATA dump X X      
Table 2. Requirement matrix based on problem type and product component
Component area Abend Incorrect output Performance Function loss Connectivity
Application monitoring RKLVLOG

Dump

RKLVLOG

Dump

Screen Shots1

N/A

RKLVLOG

Screen Shots

cinfo output

TEPS Db

Export

N/A
Cache CU stats

RKLVLOG

Dump

RKLVLOG

Dump

Screen Shots

LISTDATA6

RKLVLOG

Dump

Traces2

RKLVLOG

Screen Shots

cinfo output

LISTDATA6

N/A
Tape & VTS

RKLVLOG

Dump

SMF Record

Dump4

BVIR Dump4

RKLVLOG

Dump

Screen Shots

SMF Record

Dump4

BVIR Dump4

N/A

RKLVLOG

Screen Shots

cinfo output

N/A
DASD performance

RKLVLOG

Dump

RKLVLOG

Dump

Screen Shots

N/A

RKLVLOG

Screen Shots

cinfo output

N/A
DASD Space

RKLVLOG

Dump

RKLVLOG

Dump

Screen Shots

RKLVLOG

Dump

Traces2

RKLVLOG

Screen Shots

TEPS Db

Export

N/A
DADb

RKLVLOG

Dump3

RKLVLOG

Dump3

Screen Shots1

RKLVLOG

Dump3

Traces2

RKLVLOG

Screen Shots

TEPS Db

Export

N/A
Dataset group

RKLVLOG

Dump3

RKLVLOG

Dump3

Screen Shots1

RKLVLOG

Dump3

Traces2

RKLVLOG

Screen Shots

cinfo output

TEPS Db

Export

N/A
SMS

RKLVLOG

Dump

RKLVLOG

Dump

Screen Shots

N/A

RKLVLOG

Screen Shots

N/A
HSM

RKLVLOG

Dump

RKLVLOG

Dump

Screen Shots

N/A

RKLVLOG

Screen Shots

N/A
RMM

RKLVLOG

Dump3

RKLVLOG

Dump3

Screen Shots1

RKLVLOG

Dump3

Traces2

RKLVLOG

Screen Shots

cinfo output

TEPS Db

Export

N/A
Toolkit

RKLVLOG

Dump

RKS3DATA Dump

RKLVLOG

Dump

Screen Shots1

RKS3DATA Dump

N/A

RKLVLOG

Screen Shots

cinfo output

TEPS Db

Export

N/A
OM II Interface

RKLVLOG

Dump

RKLVLOG5

Dump

Screen Shots

RKLVLOG5

Dump3

Traces2

RKLVLOG

Screen Shots

RKLVLOG5

Historical

RKLVLOG

Dump

RKLVLOG

Dump

Screen Shots1

RKLVLOG

Dump3

Traces2

RKLVLOG

Screen Shots

N/A
Note:
  1. Should include screen shots of relevant definition dialogs, as well as the errant workspaces. For instance, documentation for incorrect output in the Dataset Group Summary should contain screen shots of the dialog where the groups are defined, as well as the workspace showing the incorrect values.
  2. See the section on Traces for information about setting traces for specific component areas.
  3. Some components store data in data spaces and the dump created for the abend may not contain the data space, therefore you may need to create a separate console dump to capture the data space and send it together with the abend dump. See the section on Dump Creation for more information.
  4. If your problem involves an IBM VTS that pre-dates the TS7700 series, statistics are extracted from SMF Type 94 records. Please use IFASMFDP to dump all Type 94 records from one of your MAN datasets and submit it with your other documentation. See the section on Dumping SMF Records for more information.

    If your problem involves an IBM TS7700 series VTS, statistics are extracted by a BVIR dataset which is created every interval. Please use a batch job to mimic this collection process and submit the output BVIR data set to support along with your other documentation. See the section on Creating a BVIR data set in batch mode for more information.

  5. OMEGAMON for Storage gathers cache information using IBM IDCSS01 service. A good way to determine whether a problem in collecting cache statistics is due to an OMEGAMON bug is to use another utility that relies on IDCSS01. IDCAMS LISTDATA command does this. See the section on Running LISTDATA for information on setting up a job to test statistics collection on a controller.